Future releases of the OA cmdlets will include the following:
Addition of new cmdlets
Additional supported hardware and features
Issues and workarounds
Issue: In OA firmware version 4.0 and later the Add-HPOASSHKey and
Start-HPOASSHKeyDownload cmdlets might return the error The submitted file is not a valid
SSH key.
Workaround: Continue to retry the cmdlet. It may take up to 10 retries to successfully execute the
cmdlet.
Issue: The HPiLOCmdlets uninstall can modify the PSModulePath environment variable to remove
the path to the HPOACmdlets module. This causes the HPOACmdlets (if installed) to not be
available unless you use Import-Module to locate them for PowerShell.
Workaround: If this occurs, the HPOACmdlets should be reinstalled. To prevent this from happening,
install the HP iLO Cmdlets v1.1.0.1. To download the cmdlets go to http://www.hp.com/go/
powershell.
Issue: The Set-HPOAEnclosure cmdlet will sometimes not set values on an OA when multiple
parameters are specified.
Workaround: Set one parameter value at a time instead.
Issue: The Set-HPOASessionTimeout cmdlet does not currently have a way to disable the
session timeout.
Workaround: No work around is available.
Issue: The Get-HPOAServerPortMap cmdlet does not display the port mapping for fiber channel
cards correctly.
Workaround: No work around is available.
Prerequisites
For prerequisites, see the HP Scripting Tools for Windows PowerShell User Guide OA Cmdlets.
Installation instructions
For installation instructions, see the HP Scripting Tools for Windows PowerShell User Guide OA
Cmdlets.
Documentation feedback
HP is committed to providing documentation that meets your needs. To help us improve the
documentation, send any errors, suggestions, or comments to Documentation Feedback