HP StorageWorks SB40c Storage Blade Maintenance and Service Guide (433903-002, April 2009)
4. Replace the component by reversing the removal procedure.
Cache module battery pack
This component uses a nickel metal hydride (NiMH) battery pack.
WARNING!
There is a risk of explosion, fire, or personal injury if a battery pack is mishandled. To reduce this
risk:
• Do not attempt to recharge the batteries if they are disconnected from the controller.
• Do not expose the battery pack to water, or to temperatures higher than 60°C (140°F).
• Do not abuse, disassemble, crush, or puncture the battery pack.
• Do not short the external contacts.
• Replace the battery pack only with the designated HP spare.
• Battery disposal should comply with local regulations.
To remove the component:
1. Power down the partner server blade.
2. Remove the SB40c.
3. Remove the access panel.
4. Remove the battery pack.
Storage blade preparation22