HP Mainframe Connectivity Design Guide
FICON director database size
Table 11 (page 42) describes the database size rules for B-series FICON directors in a fabric.
Table 11 Database size rules for B-series FICON directors
DescriptionRule number
SFOS—With security enabled in a fabric, the maximum security database size is as follows:1
• If the fabric contains any 1 Gb/s directors, the maximum size is 32 KB, with only 16 KB active.
The maximum number of DCC policies is 620.
• If the fabric contains 2 Gb/s or 4 Gb/s directors only, the maximum size is 128 KB, with 64 KB
active.
• With Fabric OS 6.x, the maximum size is 1 MB.
This database, which stores DCC, SCC, and FCS policies, can support ACL security settings for
environments with up to 14,000 attached devices. This feature is not supported with the 4/16 SAN
Switch.
NOTE: Starting with firmware 5.2.0a, ACL has replaced SFOS.
Advanced Zoning—The maximum zoning database size is as follows:2
• If all directors in a fabric are using 5.2x (or later) firmware, the database size must not exceed 1
MB.
• If the fabric contains 1 Gb/s directors with 2.6.1x (or later) firmware, the database must not exceed
96 KB.
• If the fabric contains 2 Gb/s or 4 Gb/s directors with 2.6.1x (or later) firmware, the database
must not exceed 256 KB.
NOTE: Use the cfgsize command to determine the size of the zoning database.
ISL maximums for B-series FICON directors
You can use all ports on all B-series FICON directors as ISLs, with a maximum of 50% of the ISLs
configured to the same destination director.
NOTE: Some directors require licensing for additional ISL ports.
Zoning limits and enforcement
Table 12 (page 42) describes zoning enforcement for B-series FICON directors.
Table 12 Zoning enforcement for B-series FICON directors
CommentsEnforcementConfigurationDirector/switch
Hard zoning
Access authorization at
frame level in hardware
Define zones using domain
number, port number
HP StorageWorks
DC SAN Backbone Director and DC04
SAN Director
Hard zoning
Access authorization at
frame level in hardware
Define zones using WWNs
only
SAN Director 2/128, 4/256
Core Switch 2/64, 4/64
Soft zoning, Name Server
discovery-based
Name Server
directory-based
Define zones using
combination of domain/port
numbers and WWNs
SAN Switch 2/32, 4/32
authentication, login
protection
authentication, login
authentication
Zoning guidelines for B-series FICON directors
To configure B-series FICON director zoning, observe the following best practices:
• All FICON ports should be in the same zone.
• For FICON-only fabrics, the fabric should be in one zone.
• The FICON zone requires port-based routing.
42 B-series FICON directors and fabric rules