HP Mainframe Connectivity Design Guide
P9500 configuration with PAVs
A P9500 array configured for 2,048 mainframe volumes with 3 PAVs for each volume requires
32 LCUs, each with 64 base addresses and 192 PAV (alias) addresses.
Table 69 (page 109) describes a sample P9500 configuration with PAVs. All numbers are
hexadecimal unless noted otherwise.
Table 69 Sample P9500 configuration with PAVs
Base or PAV
SSID
2
Device
nl
LCU
UNITADD
(starting
nl
CUADDCUNUMBER
Device
nl
number address
address,
range
1
)
Base
1000
00–3F
00
00,64
001000
1000–103F
PAV40–FF40,1921040–10FF
Base
1001
00–3F
01
00,64
011100
1100–113F
PAV40–FF40,191140–11FF
Base
1002
00–3F
02
2 00,64
021200
1200–123F
PAV40–FF40,1921240–12FF
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
.
nl
........
Base
1030
00–3F
1E
00,64
1E2E00
2E00–2E3F
PAV40–FF40,1922E40–2EFF
Base
1031
00–3F
1F
00,64
1F2F00
2F00–2F3F
PAV40–FF40,1922F40–2FFF
1
The range is a decimal number.
2
The SSID value is supplied by the system programmer.
NOTE: Each PAV address counts as an address on the P9500 array. How you configure PAVs
on the mainframe depends on the mainframe model and operating system version.
P9500 configuration rules 109