HP StorageWorks Reference Information Storage System V1.1 Administrator Guide (February 2005)
Services tools folder Chapter 2:
Platform Control Center
HP StorageWorks Reference Information Storage System Administrator Guide, February 2005 2-117
4. Determine which smart cells failed and can be restored:
a. In the
MBean
view for the primary controller, click the button next to
ListBrokenGroups
. Groups that failed and have not been recovered are
listed.
b. Copy
GroupIDs
and
Roles
of broken groups.
c. Click
Back to MBean view
.
4. Restore the smart cell:
a. Under the
RestoreSmartCellUsingGroupIDAndRole
attribute, enter the
group ID in the first field and the role in the second field.
b. Click
Invoke
.
c. If the restore is successful, a confirmation message appears. Note the
restore target information.
d. If an error occurs, verify that the group ID and role are correct. If the
information is correct, verify that the smart cell needs restoring and
there is a free smart cell.
5. Verify that the restore process is running correctly or has completed:
a. In the
View Cell Space
view, locate the restored smart cell listed in the
confirmation message.
b. If the smart cell assigned is not in the restore state, the restore
process completed and no further action is required. Otherwise, click
the link to the smart cell in the restore state.
c. From the
MBean
list, click
BackupSystemMBean
. The
MBean
view
appears.
d. Verify that the
RunningState
attribute is
3
and the
FailureReason
attribute is
No Failure
. This indicates the restore process is occurring
normally.
If the
RunningState
attribute is
5
, the restore process failed. Check the
FailureReason
attribute for the cause.
MBean view
This view shows operations (methods) and attributes exposed by a particular
managed object (MBean or JBoss component) for remote management
purposes.