HP XP24000/XP20000 Virtual LVI/LUN (VLL) and Volume Shredder User Guide (T5214-96094, November 2011)
Table 2 CV Capacity by Emulation Types (for Mainframe System) (continued)
Number of control cylinders
(Cyl)
Maximum CV capacity (Cyl)Minimum CV capacity (Cyl)Emulation type
63,33913390-3A
63,33913390-3B
63,33913390-3C
63,33913390-3R
2510,01713390-9
2510,01713390-9A
2510,01713390-9B
2510,01713390-9C
2332,76013390-L
2332,76013390-LA
2332,76013390-LB
2332,76013390-LC
5365,52013390-M
5365,52013390-MA
5365,52013390-MB
5365,52013390-MC
Table 3 CV Capacity by Emulation Types (for Open System)
Number of control cylinders
(Cyl)
Maximum CV capacityMinimum CV capacity (CYL)Emulation type
0 KB (0 Cyl)4,294,967,040 KB (4 TB)48,000 KBOPEN-V
5,760 KB (8 Cyl)2,403,360 KB36,000 KB (50 Cyl)OPEN-3
19,440 KB (27 Cyl)7,175,520 KB36,000 KB (50 Cyl)OPEN-8
19,440 KB (27 Cyl)7,211,520 KB36,000 KB (50 Cyl)OPEN-9
13,680 KB (19 Cyl)14,226,480 KB36,000 KB (50 Cyl)OPEN-E
NOTE: Virtual LUN operations are not available for OPEN-L volumes.
SSID Requirements
The HP storage system is configured with one SSID for each of 256 devices and up to four SSIDs
per CU image. Each SSID must be unique within each host system. Table 4 (page 9) shows the
relationship between emulation types of controllers and SSIDs.
Table 4 SSID Requirements
LVI/LUN SupportSSID requirementController emulation type
3390-3, 3390-3A, 3390-3B, 3390-3C,(0004)
x
- (FFFD)
x
3990-6, 3990-6E
3390-9, 3390-9A, 3390-9B, 3390-9C,
OPEN-3, OPEN-8, OPEN-9, OPEN-E, and OPEN-V volumes
3380-3, 3380-3A, 3380-3B, 3380-3C,(0004)
x
- (FFFD)
x
2105-F20, 2107
Overview of Virtual LVI/LUN 9