HP XP24000/XP20000 Snapshot User Guide (T5213-96033, November 2011)

Table 34 Cause of Error and the Result of RAID Manager Command (SSB) (continued)
Cause of ErrorRAID Manager CommandSSB2SSB1
Since the Max LBA size of
the volumes you specified as
paircreate,
pairsplit,
9752
the XP Snapshot P-VOL and
pairresync,
S-VOL is different, the
command ends abnormally.
pairresync -
restore
Since the number of slots of
the volumes you specified as
paircreate,
pairsplit,
9753
the XP Snapshot P-VOL and
pairresync,
S-VOL is different, the
command ends abnormally.
pairresync -
restore
Since you specified the XP
Thin Provisioning V-VOL as
paircreate,9754
the XP Snapshot S-VOL, the
pair cannot be created.
Since you specified the XP
Business Copy reserved
All commands9756
volume as the XP Snapshot
P-VOL, the command ends
abnormally.
Since you specified the XP
Auto LUN Software source
All commands9757
volume as the XP Snapshot
P-VOL, the command ends
abnormally.
For information about using
XP Auto LUN, contact HP
technical support (see
(page 110)).
Since you specified the XP
Auto LUN target volume as
All commands9758
the XP Snapshot P-VOL, the
command ends abnormally.
For information about using
XP Auto LUN, contact HP
technical support (see
(page 110)).
Since you specified the XP
Auto LUN reserved volume
All commands9759
as the XP Snapshot P-VOL,
the command ends
abnormally.
For information about using
XP Auto LUN, contact HP
technical support (see
(page 110)).
Since you specified the XP
Business Copy P-VOL as the
All commands975a
XP Snapshot S-VOL, the
command ends abnormally.
Since you specified the XP
Business Copy S-VOL as the
All commands975b
104 Troubleshooting