HP XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, November 2011)

Table 67 Error Codes Part Code 8105 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
0WCorrect the group name.The group name does not
exist.
57528105
0WCorrect the port ID and the
group ID.
There is a difference between
the current port ID/group ID
and the specified one.
57538105
0WCorrect the CU and LDEV.The intermediate volume
cannot be specified as a
command device.
57548105
0WTurn on the security switch on
this port.
The security switch on the
port remains off. Turn the
switch on.
57558105
0WAdd the WWN to another
port.
The number of WWN cannot
exceed 255 per port.
57568105
0WCorrect the WWN.The same WWN is already
registered.
57578105
0WCorrect the group ID.No name can be added to
the group ID (00).
57588105
0WCorrect the name.The same name is already
registered.
57598105
0WCorrect the WWN.The WWN does not exist.57618105
0WCorrect the name.The name does not exist.57628105
0WAdd the LUN to another
group or another port.
The number of LUN cannot
exceed 512 per port or 256
per host group.
57648105
0WCorrect the LUN.The LUN is already used.57658105
0WCorrect the CU and LDEV.The specified CU:LDEV is
invalid.
57668105
0WCorrect the LUN.The LUN does not exist.57678105
0WCorrect the LUN.There is a difference between
the current LUN and the
specified LUN.
57688105
0WCorrect the group ID.The group cannot be added.57698105
0WSet the port attribute to target
in advance.
The port cannot be changed
because the port is an
initiator port.
57708105
0WThe PCB mode value is
invalid. Specify a correct
value.
The setting cannot be
performed, because an
invalid PCB mode is set to the
specified CHA.
57718105
0WCorrect the CU and LDEV.The system LU cannot be
used.
57858105
0WCorrect the name of port.The path can be defined only
for the A, E, J or N port.
57868105
0WCorrect the CU and LDEV.The intermediate volume
cannot be specified as a
command device.
57898105
Remote Web Console Error Codes 395