Table 64 Error Codes Part Code 7105 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
0iVary the S-VOL offline from
the mainframe host, and then
issue the command again.
Cannot perform Resync or
Suspend operation because
of the path group setting.
85127105
0iVary the S-VOL offline from
the mainframe host, and then
issue the command again.
The command has been
rejected, because the
specified S-VOL is used by the
host.
85137105
0iDelete the Reserve volume.No reserved volume can be
allocated.
85147105
0iCheck the contents, and retry.The number of cylinders in the
reserved volume exceeds the
maximum.
85157105
0iCheck the contents, and retry.The number of S-VOL
cylinders exceeds the
maximum.
85167105
0iCheck the contents, and retry.The number of T-VOL
cylinders exceeds the
maximum.
85177105
0iCheck the emulation type.You cannot create a pair,
because the track format is
85187105
different for each. Make sure
that the specified emulation
type is the same for both.
0iCheck the volume capacity.You cannot set a pair
because the number of
85197105
cylinders is different for each.
Make sure that the capacity
is the same for both.
0iSpecify the volume with the
same emulation type, and
retry the operation.
You cannot set a pair,
because the volume type is
different for each.
85207105
0iCheck the contents, and retry.The number of multiple copy
jobs exceeded the maximum.
85217105
0iSpecify the supported
emulation type.
The emulation type of the
S-VOL is not supported.
85227105
0iSpecify the supported
emulation type.
The emulation type of the
T-VOL is not supported.
85237105
0iSpecify the supported
emulation type.
The emulation type is not
supported.
85247105
0ECall HP technical support.An internal logic error
occurred.
85257105
0ECall HP technical support.An internal logic error
occurred.
85267105
0ECall HP technical support.An internal logic error
occurred.
85277105
0ECall HP technical support.An internal logic error
occurred.
85287105
0ECall HP technical support.An internal logic error
occurred.
85297105
Remote Web Console Error Codes 357