HP XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, November 2011)
Table 54 Error Codes — Part Code 6505 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
0iCheck the number of the
journal volumes in the
No more journal volumes can
be registered, or too many
volumes are selected.
580356505
specified journal groups.
Also, check the number of the
selected volumes.
0iCheck the emulation type of
the specified volume.
The device emulation type of
the specified volume is not
supported.
580366505
0iCheck the status of the
specified journal group.
The specified journal group
cannot be deleted because a
data volume exists.
580376505
0iCheck the number of
registered path group IDs.
No more path group IDs can
be registered.
580386505
0iSpecify another volume.The specified volume is
already used as a journal
volume or a data volume.
580396505
4ECheck the SSB log, and then
call HP technical support.
An internal error occurred.580406505
0iReduce the number of
requests to be processed at
Too many requests. Reduce
the number of requests to be
580646505
one time. Then retry the
operation.
processed at one time. After
that, retry the operation.
0iCheck the specified LDEV
number.
Invalid parameter (LDEV
number).
580656505
0iCheck the specified journal
group number.
Invalid parameter (Journal
Group number).
580666505
0iCheck the specified mirror ID.Invalid parameter (Mirror ID).580676505
0iCheck the specified JNL
Control parameter.
Invalid parameter (Journal
Control).
580686505
0iCheck the specified Suspend
Condition parameter.
Invalid parameter (Suspend
Condition-Journal Full).
580696505
0iCheck the specified Suspend
Condition parameter.
Invalid parameter (Suspend
Condition-Master Journal
Failure).
580706505
0iCheck the specified Suspend
Condition parameter.
Invalid parameter (Suspend
Condition-Restore Journal
Failure).
580716505
4WThe current configuration of
the storage systems and the
The pair status has not
changed yet. Check the
580726505
current status of linesconfiguration of the
connecting the storagesubsystems and the status of
systems may not satisfy thelines connecting the
operating conditions. Checksubsystems, and then check
the configuration of thewhether the status of the XP
storage systems and theContinuous Access pair is
changed. status of lines connecting the
storage systems, and then
check whether the status of
the XP Continuous Access
pair is changed.
268 Remote Web Console for Storage System Messages and Error Codes