HP XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, November 2011)
Table 50 Error Codes — Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
4iThe operation failed for one
or more of the volumes,
Some volumes were not
deleted by the Delete Pair
(Pairsplit-S) operation.
88576005
because either the pair status
of the volume is SEQCHK or
the consistency time of the
volume does not match the
consistency time of the CT
group. Verify the status of the
failed volumes. If necessary,
retry the delete pair operation
with the volume or the group
option.
4iThe operation failed for all of
the volumes, because either
All volumes were not deleted
by the Delete Pair (Pairsplit-S)
operation.
88586005
the pair status of the volume
is SEQCHK or the consistency
time of the volume does not
match the consistency time of
the CT group. Verify the
status of the failed volumes.
If necessary, retry the Delete
Pair operation with the
volume or the group option.
4iThe pair status does not allow
this operation. Refresh and
Delete Pair (Pairsplit-S)
operation with C/T option
88596005
confirm the pair statusfailed because some R-VOLs
information on the windowin the group are in Duplex
first. If the R-VOL status is
valid, retry the operation.
(PAIR) or Pending (COPY)
status.
4ECall HP technical support.An internal error occurred.88606005
4ECall HP technical support.An internal error occurred.88616005
4iThe delete pair (Pairsplit-S)
operation failed. A few
Wait a few minutes and retry
the Delete Pair (Pairsplit-S)
operation.
88626005
minutes later, refresh the
window, confirm if the
specified volumes are in the
permissible status, and then
retry the operation.
4EThe Remote Console
computer detected an
Unknown Error Code.88636005
unknown error code. Call HP
technical support.
4ECall HP technical support.An internal error occurred.88646005
4ECall HP technical support.An internal error occurred.88656005
4ECall HP technical support.An internal error occurred.88666005
4ECall HP technical support.An internal error occurred.88676005
4EThe operation failed because
a duplicate CT Group is
Duplicate CT Group# (A CT
Group has been already
active in MCU).
88686005
already active in the MCU.
Verify the status of the CT
group and retry the
operation.
Remote Web Console Error Codes 227