HP XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, November 2011)

Table 50 Error Codes Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
Mainframe or Business
Copy.
A volume of
ShadowImage for
Mainframe or Business
Copy in Reverse Copy
status.
A volume of FICON(R)
Data Migration.
4iCheck the status of the
specified M-VOL from the
host or the SVP.
If the M-VOL is the
ShadowImage for
Mainframe/Business
87976005
Copy/Compatible
FlashCopy(R) T-VOL, one
S-VOL must be paired with
one T-VOL.
4iThe Add Pair operation failed
because the MCU is already
The MCU is already used for
ShadowImage for
87986005
being used for XP BusinessMainframe/Business
Copy/FlashCopy Mirroring.Copy/Compatible
FlashCopy(R). Verify the status of the MCU
and retry the operation.
4EVerify the status of the
specified M-VOL.
The M-VOL is already in use
for Auto LUN.
87996005
4EVerify the status of the
specified R-VOL.
The R-VOL is already in use
for Auto LUN.
88006005
4iVerify the status of the
specified R-VOL. If the device
The R-VOL is reserved, or the
RCU or the path between
88016005
is not reserved, retry the
operation.
MCU-RCU is in a heavy load
condition.
4EThe add pair operation failed
because the CT Group is not
CT group is not active.88026005
active. Add the CT group,
and then retry the operation.
4iThe add pair operation failed
because there are too many
Too many RCUs in this CT
Group.
88036005
RCUs in this CT group. If the
timer type is None, and then
4 RCU have already been
added. If the timer type is
Local or System, and then 1
RCU has already been
added. Check configuration
of CT group numbers already
used on both MCU and RCU.
Register a new CT group.
4iThe resume pair operation
failed. The volume and the
Copy mode cannot be
changed.
88046005
copy mode must be either
both asynchronous or both
synchronous. Verify that the
status of the volume and the
copy mode match, and then
retry the operation.
Remote Web Console Error Codes 221