HP XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, November 2011)
Table 50 Error Codes — Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
it is off, set it on and retry. If
it cannot be set on, call HP
technical support.
4iCheck the DFW status of the
R-VOL from the host. If it is
R-VOL DFW status is not
active.
87636005
off, set it on and retry. If it
cannot be set on, call HP
technical support.
4WConfirm the status of the
specified R-VOL.
The specified R-VOL is not
usable.
87646005
4iThe device emulation type of
the R-VOL does not support
XP Continuous Access is not
supported under the R-VOL
Device emulation type.
87666005
XP Continuous Access. Call
HP technical support.
4EThe RCU containing the
R-VOL is being used as the
The RCU is still in another XP
Continuous Access condition.
87686005
RCU for XP Continuous
Access. Verify the status of
the RCU, if necessary delete
the RCU, and then retry the
operation.
4EThe RCU containing the
R-VOL is being used as the
The RCU is still in another XP
Continuous Access condition.
87696005
RCU for XP Continuous
Access. Verify the status of
the RCU.
4iClick [OK] to acknowledge
the message, and then retry
The Cache on the MCU is
automatically recovering.
87706005
the operation after the cache
has been recovered.
Wait a few minutes then retry
again.
4iThe R-VOL option change
operation failed (only the
R-VOL option change
operation failed. Only M-VOL
87716005
M-VOL option was modified),option was modified because
because the RCU side doesRCU side did not support a
not support the display fence
level function.
fence level displaying
function.
4EThe pair option change
operation failed, either
Change pair operation failed
due to communication error
or the R-VOL status is invalid.
87726005
because a communication
error occurred or because the
R-VOL status is not valid.
Verify the status, and view the
License Key window at the
RCU side to check the
licensed capacity for Volume
Retention Manager for
Mainframe. If the licensed
capacity for Volume Retention
Manager for Mainframe is
insufficient, purchase a
license key for a larger
capacity.
4iResume the pair for the
M-VOL, and then retry the
operation.
Pair change was refused
because M-VOL is
suspended.
87736005
218 Remote Web Console for Storage System Messages and Error Codes