HP XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, November 2011)
Table 50 Error Codes — Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
4iInstall the program product
key in the MCU.
The Fibre-XP Continuous
Access function is not
87336005
installed in the specified
MCU.
4iInstall the program product
key in the RCU.
The Fibre-XP Continuous
Access function is not
installed in the specified RCU.
87346005
4ECheck the serial number,
SSID and link address of the
Invalid RCU serial number,
SSID, Link Address or
Controller ID.
87356005
RCU, and set the correct
value. Then retry the
operation. If the same error
occurs, call HP technical
support.
4iDelete all XP Continuous
Access volume pairs of the
The specified RCU or SSID
contains some XP Continuous
Access volume pairs.
87366005
specified RCU or SSID, and
retry the operation.
4ECall HP technical support.An internal error occurred.87376005
4iThe emulation type of the
MCU does not support XP
XP Continuous Access is not
supported under the MCU
Controller emulation type.
87386005
Continuous Access. To use XP
Continuous Access, Call HP
technical support.
4iThe MCU NVS status
specified by the host is not
NVS status of MCU is not
active.
87396005
active. Set the NVS to on for
the MCU, using any attached
host, and then retry the
operation.
4iThe RCU NVS status specified
by the host is not active. Use
NVS status of RCU is not
active.
87406005
any attached host to set the
NVS to on for the MCU, and
then retry the operation.
4iCheck the path status
between the MCU and the
RCU.
The logical paths between the
MCU and RCU are not
established.
87416005
4WCheck the status of the
M-VOL tracks, and clear the
pinned tracks.
Pinned track(s) exists on the
M-VOL.
87426005
4WCheck the status of the R-VOL
tracks, and clear the pinned
tracks.
Pinned track(s) exists on the
R-VOL.
87436005
4WThe M-VOL is not available
for the requested operation,
The specified M-VOL
condition is not valid for XP
Continuous Access.
87446005
because of one or more of
the following reasons:
• The volume is blocked.
• The volume is under
maintenance.
Remote Web Console Error Codes 215