HP XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, November 2011)
Table 34 Error Codes — Part Code 3005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
6EWhen the pool information
cannot be acquired, do the
following:
Acquisition of the pool
information has failed.
Pool information cannot be
acquired when:
584723005
• Check the installation
status of the V-VOL
• V-VOL management area
is not initialized.
management area, when
the V-VOL management
area is not initialized.
• V-VOL management area
is not installed.
• Check the installation
status of the V-VOL
management area, when
the V-VOL management
area is not installed.
6ECheck the error message of
the logical volumes in the
Pool.
An error occurred when
setting the Pool. Check the
error message of the logical
volume(s) in the Pool.
584733005
6ECheck the amount of free
space in Pool management
The capacity of shared
memory is insufficient or an
584743005
block in the Pool window.error occurred during SVP
processing. Install additional shared
memory if the free space is
insufficient.
Call HP technical support if
the capacity of shared
memory is not insufficient.
6EInstall the PCB for fiber port
and retry the operation.
The PCB for fibre port is not
installed.
584753005
3EIf this problem persists, call
HP technical support.
A communication time-out
error occurred in the storage
584913005
system. Wait for a while, and
then retry the operation.
6EDelete the XP Snapshot pairs,
and then retry the operation.
V-VOL management area is
being used.
585703005
Delete the XP Snapshot
pair(s), and then retry the
operation.
6ECheck the pool-VOL setting.The specified operation
cannot be executed because
the Pool-VOL is not mounted.
585713005
2EWait awhile, and retry the
operation. If the error
An error occurred during the
communication with the
585723005
occurred in the operation ofstorage system. Wait awhile,
and retry the operation. the pool, initialize the V-VOL
If the error occurred in the
operation of the pool,
management area, refresh
the configuration by clicking
[Refresh All] on the File menu,
and retry the operation.
initialize the V-VOL
management area, refresh
the configuration by clicking
[Refresh All] on the File menu,
and then retry the operation.
3ECheck whether the
DKCMAIN microcode version
This function is not supported.585733005
Remote Web Console Error Codes 139