HP XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, November 2011)
Table 26 Error Codes — Part Code 1005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
6ECorrect the settings, and then
retry the operation.
To define a path to the
volume from an iSCSI port,
11901005
the volume must be
read/write-enabled and also
usable as an S-VOL
(secondary volume).
6ECorrect the settings, and then
retry.
No information can be
changed about this external
11941005
port because the port has an
external volume.
6ECorrect the settings, and then
retry.
You cannot set high-speed
mode to a package including
an external port.
11971005
6ECorrect the settings, and then
retry.
Since a path is defined to an
external LU, you cannot set
high-speed mode.
11981005
6ECheck the setting.The path cannot be set to the
specified volume because the
11991005
volume is not an
open-systems volume.
6EChange the parameter to a
path where the High Speed
The selection of High Speed
mode/MIX mode is invalid.
12011005
mode/MIX mode can be set,
and then retry the operation.
The specified port cannot be
changed to High Speed
mode/MIX mode.
6EThe configuration information
has been already changed.
High Speed mode/MIX mode
was specified. However,
12031005
Check the settings, and
request the setting of the
there are addresses to which
High Speed mode/MIX mode
cannot be set in the Fibre
configuration information
again.
Addresses of the specified
ports.
6EThe configuration information
has been already changed.
High Speed mode/MIX mode
was specified. However,
12041005
Check the settings, and
request the setting of the
there are topologies to which
High Speed mode/MIX mode
cannot be set in the
configuration information
again.
topologies of the specified
ports.
6ETo add a path, change the
attribute of the specified port
to Target or RCU Target.
You could not add the path
to the initiator or external
port.
13501005
6ECannot set to high-speed
mode because the port
The high-speed or
initiator/external mix mode
13511005
attributes are mixed, orcannot be set to the specified
cannot set to internal/externalport because of the attribute
of the port. mix mode because the
combination of port attributes
is different. Check the port
attributes, and then retry the
operation.
6EBecause the port you are
trying to set is for XP
Logical paths remain on the
Fibre-MCU port. This
13521005
Continuous Access, you mustoperation may cause a fatal
Remote Web Console Error Codes 105