HP StorageWorks XP24000/XP20000 Remote Web Console Users Guide (AE131-96067, July 2009)
Execution Results
The execution results of the CFL Extension commands are exported to the following area in the output
file:
• After the semicolon on each row
• The row below the row where an error occurred
• The following table describes the exported contents
Table 26 Exported Contents of the Execution Results
Exported ContentDescriptionRow
Normal end: Finished normally.
Warning(xxxx-yyyyy): Errors occurred on some rows.
Error(xxxx-yyyyy): Errors occurred on every row.
Indicates the overall result of
the spreadsheet.
Declaration
For the CFLCHK command:
• Check OK: Finished normally.
• Check NG(xxxx-yyyyy): An error occurred on this row.
For the CFLGET or CFLSET command:
• Normal end: Finished normally.
• Error(xxxx-yyyyy): An error occurred on this row.
Indicates the overall result of
the spreadsheet.
Parameter
(xxxx-yyyyy) indicates part codes and error codes.
Examples of execution results are as follows:
• Case 1: An operation tag has an error
The following example shows execution results when an operation tag has an error. To identify
where an error occurred, find the row above the row that begins with the #^ characters. In this
example, an error occurred in the SuspendPair tag.
#!Version 05_02_01,CFL_RemoteCopyJournalMF,PairOperation,;Error(6505-66004)
[SerialNumber]
64040,;Check OK
[Suspend-Pair]
#^,;Check NG(6505-66004)
00,04,40,01,P-VOL,00,64040,Group,Disable,Flush,;
• Case 2: A parameter has an error
The following example shows execution results when a parameter has an error. To identify where
an error occurred, find all the rows that display an error after the semicolon. In this example, errors
occurred on the first and fourth row in the SuspendPair tag.
#!Version 05_02_01,CFL_RemoteCopyJournalMF,PairOperation,;Warning(1305-66578)
[SerialNumber]
64040,;Normal end
[SuspendPair]
00,04,40,01,P-VOL,00,64041,Volume,Disable,Flush,;Error(6505-58075)
XP24000/XP20000 Remote Web Console User's Guide 151