HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, May 2011)
Table 67 Error Codes — Part Code 8105 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
2EWhen the PORT information
(Fibre Address/Fibre
Topology/Channel Speed) is
set, multiple change
instructions are set to the
same port. The error does not
occur normally because it is
guarded in the screen. In the
unlikely event that this error
occurs, contact HP technical
support.
An error occurred. If this
problem persists, call HP
technical support.
11358105
2EWhen CHA high-speed mode
is set, multiple change
instructions are set to the
same port. The error does not
occur normally because it is
guarded in the screen. In the
unlikely event that this error
occurs, contact HP technical
support.
An error occurred. If this
problem persists, call HP
technical support.
11368105
6EThe configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
Failed to from a LUSE volume
because the number of LUSE
volumes exceeds the
maximum that can be set in
a disk array subsystem.
11378105
6WRelease the Port Group
setting.
Nothing is set. Create a
setting and then execute it.
11408105
6EConnect settings, and then
retry.
The volume cannot be
configured as a command
device because the volume
does not have Read/Write
attribute.
11708105
6ECorrect the specified
contents, and request again.
The specified path cannot be
added, because the volume
is used by a XP Continuous
Access pair.
11818105
0WCorrect the port information
or the PCB mode information.
The port information is
inconsistent with PCB mode
information.
11838105
0WCorrect the port information
or the PCB mode information.
The port information is
inconsistent with PCB mode
information.
11848105
6ECorrect the settings, and then
retry.
You cannot add paths to XP
Continuous Access or
Business Copy pair volumes.
11938105
6ECorrect the settings, and then
retry.
Since a path is defined to an
external LU, you cannot set
high-speed mode.
11988105
5EChange the parameter to a
path where the High Speed
mode/MIX mode can be set,
and then retry the operation.
The selection of High Speed
mode/MIX mode is invalid.
The specified port cannot be
changed to High Speed
mode/MIX mode.
12018105
402 Remote Web Console for Storage System Messages and Error Codes