HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, May 2011)
Table 66 Error Codes — Part Code 8005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
6ECheck the settings, and then
retry the operation.
The parity group that contains
the volume(s) to which Cache
Residency Manager is set
cannot be migrated to
another CLPR.
Remove the Cache Residency
Manager settings from the
volumes, and then migrate
the parity group.
CLPR No:%s
552658005
3EIf this problem persists, call
HP technical support.
An error occurred during SVP
processing. If this problem
persists, call HP technical
support.
563018005
3EIf this problem persists, call
HP technical support.
An error occurred during SVP
processing. If this problem
persists, call HP technical
support.
563028005
3EIf this problem persists, call
HP technical support.
An error occurred during SVP
processing. If this problem
persists, call HP technical
support.
563038005
3ESelect another window. To
set this function, contact the
storage administrator.
This function cannot be used
by the storage partition
administrator.
565248005
3ETo continue the operation,
contact the storage
administrator and have the
settings across the multiple
SLPRs cancelled, and then
retry the operation.
To perform other operations,
select a function button.
Because the settings across
the multiple SLPRs are
contained, the authority has
been shifted to the storage
administrator from the
storage partition
administrator. To continue the
operation, contact the
storage administrator. To
perform other operations,
select a function button.
565258005
6ECorrect the settings, and then
retry the operation.
The resources of other SLPR(s)
cannot be accessed.
565268005
3EIf this problem persists, call
HP technical support.
An error occurred during SVP
processing. If this problem
persists, call HP technical
support.
571018005
6EIf this problem persists, call
HP technical support.
An error occurred while
connecting to the subsystem.
Wait for a while, and then
retry the operation.
585728005
6EThe microcode versions of
DKCMAIN and SVP may not
match. Check whether the
DKCMAIN microcode version
and the SVP microcode
version match.
This function is not supported.585738005
394 Remote Web Console for Storage System Messages and Error Codes