HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, May 2011)

Table 64 Error Codes Part Code 7105 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
0iStop using the specified pair
for Universal Replicator for
Mainframe, or specify a
different pair, and then retry
the operation.
The Quick Restore command
has been rejected, because
the specified pair is
composed of internal and
external volumes, and also
used as a Universal
Replicator for Mainframe
pair.
583517105
0iTo continue the operation,
release the Universal
Replicator for Mainframe pair
or the TrueCopy for
Mainframe pair, and retry the
operation.
The command was rejected,
because the specified volume
was used by Universal
Replicator for Mainframe and
TrueCopy for Mainframe.
583567105
0WIf the problem persists despite
retrying, call HP technical
support.
The storage system is in
internal process. Retry the
operation.
584517105
0iTo continue the operation,
delete all XP Snapshot pairs
and retry.
The operation failed, because
the XP Snapshot pair(s)
existed.
585187105
0iTo continue the operation,
delete all XP Snapshot pairs
and retry.
The operation failed, because
the XP Snapshot pair(s)
existed.
585197105
2EReplace the microcode, and
then retry the operation.
The operation failed, because
different versions of
microcodes coexisted in the
storage system.
585207105
2WRelease the journal volume
setting or specify another
volume.
The operation failed, because
the specified S-VOL was a
journal volume.
585337105
2WRelease the journal volume
setting or specify another
volume.
The operation failed, because
the specified T-VOL was a
journal volume.
585347105
2WRelease the journal volume
setting or specify another
volume.
The reserve volume setting
failed because the specified
volume was a journal volume.
585357105
5WCheck the requirements for
using the volume with
Universal Replicator for
Mainframe.
The operation failed because
the specified T-VOL was a
data volume of Universal
Replicator for Mainframe.
Check the requirements for
using the volume with
Universal Replicator for
Mainframe.
585367105
3EAn error occurred on the
DKC side. If the same
problem persists despite
retrying, call HP technical
support.
An error occurred on the DKC
side. If this problem persists,
call HP technical support.
585727105
3ECheck whether the
DKCMAIN microcode version
and the SVP microcode
version are mismatched.
This function is not supported.585737105
384 Remote Web Console for Storage System Messages and Error Codes