HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, May 2011)
Table 58 Error Codes — Part Code 6610 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
0WCheck the value of the path
watch time.
The value of the path watch
time is not entered or is
outside the range. Check the
value of the path watch time.
593356610
0WSpecify the correct LDKC
number.
The specified LDKC number
is incorrect. Specify the
correct LDKC number.
656636610
0WSpecify another volume.The specified volume is not
valid for this program
product. Specify another
volume.
656646610
0WCheck the monitoring setting.The specified volume is not
the volume to be monitored.
Check the monitoring setting.
656656610
0WThe microcode versions
between the DKCMAIN and
the SVP might not match.
Confirm the microcode
versions of the DKCMAIN
and the SVP.
The current microprogram
version of DKCMAIN cannot
assign remote command
devices to mirrors.
657776610
0WCheck if a remote command
device was assigned to the
specified mirror.
No more remote command
devices can be assigned to
the specified mirror.
657786610
0WCheck whether the specified
journal groups include
mirrors available to assign a
remote command device.
There are no mirrors
available to assign a remote
command device.
657796610
0WSpecify different mirror IDs in
the mirror 1 and the mirror 2
parameters.
The same mirror ID is
specified in the mirror 1 and
the mirror 2 parameters.
657806610
5WCheck the number of mirrors
registered in the specified
journal group.
The specified mirror ID
cannot be used, because the
number of mirrors that can be
registered in the specified
journal group exceeds the
maximum.
658146610
0WTo stop the operation, click
[OK]. To continue the
operation, click [Cancel].
Are you sure you want to
cancel the export?
690166610
0WCheck the number of
registered journal groups.
No more journal groups can
be registered, because the
number of registered journal
groups has reached the
maximum.
690176610
0WCheck the LDKC number for
the specified data volume,
and specify only one LDKC
number.
There are two or more LDKC
numbers for the specified
data volume. In this
operation, specify only one
LDKC number.
690186610
Remote Web Console Error Codes 341