HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, May 2011)
Table 56 Error Codes — Part Code 6510 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
0WBecause there are duplicated
paths in the added paths, the
duplicated paths will be
eliminated. Click [OK] to
continue.
You set the same path more
than once. The duplicate
paths are excluded.
93086510
0WBecause all the added paths
are redundant, the paths
cannot be added. Click [OK]
and continue.
All paths which you set have
already been registered. This
operation will terminate
because there is no path
which can be added.
93096510
0iClick [Refresh] to update the
history file. If this problem
persists, call HP technical
support.
The monitoring time is over,
but the history file is not fully
updated yet.
93276510
0iClick [OK], and then continue
the operation.
This operation is not applied
yet.
93326510
0iCheck the number of data
volumes in the journal group.
Then delete unused data
volume pairs, or register them
in another journal group.
Too many data volumes in
the journal group.
550366510
0iCheck the number of mirrors
in the journal group. Then
delete unused mirrors, or
register them in another
journal group.
Too many mirrors in the
journal group.
550376510
0iCheck the number of mirrors
in the journal group, and
then delete unused mirrors.
Too many mirrors in the
subsystem.
550386510
0iCheck the range setting. If
you specify Group, select
only one data volume pair in
the mirror.
You are specifying Group for
the range and trying to
manipulate the same mirror.
Select only one data volume
pair in the mirror when you
specify Group for the range.
550396510
0WCheck the specified controller
ID.
The specified controller ID
cannot be used.
552026510
0WThe value of Threshold of start
Async JNL must equal or be
less than the Threshold of
start Sync JNL value.
Some of the specified values
are incorrect. Two times the
value of M-JNL Cache plus
the value of R-JNL Cache must
be equal to or less than 100.
Or, the value of Threshold of
start Async JNL must be equal
to or less than the value of
Threshold of start Sync JNL.
552076510
0WSpecify the correct journal
group number.
The specified journal group
number is incorrect. Specify
the correct journal group
number.
552086510
324 Remote Web Console for Storage System Messages and Error Codes