HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, May 2011)

Table 54 Error Codes Part Code 6505 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
5WVerify the attribute of the
specified journal group.
The operation failed because
the attribute of the specified
journal group was Master &
Restore. The following options
cannot be changed for the
Master & Restore journal
group.
Data overflow watch.
Use of cache.
689056505
5ECall HP technical support.A journal volume cannot be
added to the specified
journal group in the
operation environment of the
current storage system.
689066505
5WVerify the number of mirrors
in the specified journal
group.
The operation failed because
the number of mirrors
registered in the specified
journal group exceeded the
upper limit.
689076505
5WVerify the restore journal
group of the first mirror.
The operation to create a
pair of the second mirror
failed because a restore
journal group of the first
mirror was not a journal
group for the 3DC
configuration of three XP
Continuous Access Journal
sites.
689086505
5WVerify the specified restore
journal group.
The operation failed because
a restore journal group
specified for the second
mirror was used as a restore
journal group of the first
mirror.
689096505
5WVerify the specified restore
journal group.
A pair cannot be created
because the specified restore
journal group does not
support the URxUR multi
target or the URxUR cascade
configuration.
689106505
5WVerify the specified master
journal group.
A pair cannot be created
because the specified master
journal group does not
support the URxUR cascade
configuration.
689116505
5WVerify that the Disaster
Recovery Extended is
installed in the master storage
system.
The operation failed because
the Disaster Recovery
Extended was not installed in
the master storage system.
689126505
5WVerify that the Disaster
Recovery Extended is
installed in the restore storage
system.
The operation failed because
the Disaster Recovery
Extended was not installed in
the restore storage system.
689136505
Remote Web Console Error Codes 317