HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, May 2011)

Table 54 Error Codes Part Code 6505 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
0WCheck the status of the data
volumes in the XP Continuous
Access, TrueCopy for
Mainframe, XP Continuous
Access Journal, or Universal
Replicator for Mainframe
window.
The operation to change the
status to the status ready for
Delta resync failed because
the status of the volumes was
one of the following:
The P-VOL for XP
Continuous Access and
the primary data volume
for Universal Replicator
are different.
The M-VOL for TrueCopy
for Mainframe and the
primary data volume for
Universal Replicator for
Mainframe are different.
587046505
0WCheck the status of the
specified secondary data
volume.
The Delta resync operation
failed. The specified
secondary data volume
should meet the following
requirements.
The specified volume is a
secondary data volume of
another mirror.
The pair status of the
specified volume is PSUS,
PSUE, Suspend, PAIR or
Duplex.
587056505
0WCheck the status of the
specified secondary data
volume.
The Add Pair (Paircreate)
operation or the Resume Pair
(Pairresync) operation failed
because the status of the
specified secondary data
volume was Not Ready.
587076505
0WIf the same problem persists
despite retrying, call HP
technical support.
The Add Pair (Paircreate)
operation to get ready for
Delta resync failed, or the
recovery to the status ready
for Delta resync failed. If the
same problem persists despite
retrying, call HP technical
support.
587086505
5WCheck the licensed capacity
of this program product and
the related program products.
See the user's guides of XP
Continuous Access or
TrueCopy for Mainframe for
details on the licensed
capacities.
The related program products
are:
XP Continuous Access or
TrueCopy for Mainframe
XP Continuous Access
Journal or Universal
Replicator for Mainframe
The licensed capacity of XP
Continuous Access or
TrueCopy for Mainframe on
the RCU is insufficient.
Check the licensed capacity
of this program product and
the related program products.
The related program products
are:
XP Continuous Access or
TrueCopy for Mainframe
XP Continuous Access
Journal or Universal
Replicator for Mainframe
587166505
Remote Web Console Error Codes 303