HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, May 2011)

Table 50 Error Codes Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
0W
The serial number of the
local DKC cannot be set
as the serial number of the
other DKC. Check the
input serial number of the
other DKC.
A quorum disk cannot be
registered in a same
external storage device
with a different quorum
disk ID. Check whether a
quorum disk is registered
in the selected external
storage device with a
different quorum disk ID.
The serial number of the
other DKC, which is set
from MCU (or RCU) when
registering a quorum disk,
might be different from the
serial number of the RCU
(or MCU). Check the input
serial number of the other
DKC, which is set from
MCU (or RCU) when
registering a quorum disk.
The operation failed, because
there was an error in the
specified parameter.
688276005
0WCheck the volume setting.The specified volume has
already been set to the
quorum disk.
688296005
0WCheck the volume setting.The specified volume is not a
quorum disk.
688306005
0WRelease all the pairs of XP
External Storage Access
Manager of the specified
quorum disk ID, and then
retry the operation.
The operation failed, because
the specified quorum disk
was used for XP External
Storage Access Manager.
688316005
0WRetry the operation after the
completion of discarding
zero data on the specified
volume.
The operation failed, because
the specified M-VOL was a
volume of XP Thin
Provisioning whose zero data
was being discarded.
688446005
0WRetry the operation after the
completion of discarding
zero data on the specified
volume.
The operation failed, because
the specified R-VOL was a
volume of XP Thin
Provisioning whose zero data
was being discarded.
688456005
0WWait until the initializing
process is completed, and
then retry the operation.
The operation failed, because
the specified M-VOL was
being initialized by Business
Copy or ShadowImage for
Mainframe.
688466005
0WWait until the initializing
process is completed, and
then retry the operation.
The operation failed, because
the specified R-VOL was
being initialized by Business
Copy or ShadowImage for
Mainframe.
688476005
Remote Web Console Error Codes 251