HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, May 2011)
Table 26 Error Codes — Part Code 1005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
2EThe volume that links as an
expanded LU extend over
CU#. The error does not
occur normally because it is
guarded in the screen. In the
unlikely event that this error
occurs, contact HP technical
support.
An error occurred. If this
problem persists, call HP
technical support.
10111005
6EThe configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
LU path is set to a volume
which links as an expanded
LU.
10121005
2EThe emulation type of a
volume that links as an
expanded LU is not the same.
The error does not occur
normally because it is
guarded in the screen. In the
unlikely event that this error
occurs, contact HP technical
support.
The emulation types of the
volumes combined into a
LUSE volume are not the
same.
10131005
6EThe configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
LU path is set to the releasing
expanded LU. (You need to
release the expanded LU and
path at the same time.)
10151005
2EThe specified port does not
exist. You have specified a
wrong port number. Or the
specified port type
(exclusively for mainframe)
cannot be processed in this
agent. The error does not
occur normally because it is
guarded in the screen. In the
unlikely event that this error
occurs, contact HP technical
support.
An error occurred. If this
problem persists, call HP
technical support.
10181005
2ELUN is invalid. (The specified
value is not in the
specification.) The error does
not occur normally because
it is guarded in the screen. In
the unlikely event that this
error occurs, contact HP
technical support.
An error occurred. If this
problem persists, call HP
technical support.
10201005
Remote Web Console Error Codes 103