HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96086, May 2011)
Table 23 Error Codes — Part Code 0610 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
0WSet the emulation type that
can be applied in the Set
External Volume Parameter
dialog box or Edit Policy
dialog box.
An emulation type cannot be
applied is specified.
690080610
0WAll detected external volumes
may be defined, blocked or
the capacity is insufficient.
See the manual of the
external device and check the
setting of the external volume,
or confirm whether the
program product is installed.
External volume that can be
added was not detected by
the search of Volume
Discovery.
Probable causes are:
• Detected external volumes
are all defined.
• Detected external volumes
are all blocked or the
capacity is insufficient.
• The External Storage is not
installed.
690090610
0WChange the path
configuration so that
mapping paths match
cross-subsystem paths.
The specified path
configuration cannot be set.
690100610
0WThe number of external
volumes may have reached
the maximum or the virtual
parity group (VPG) that can
be set after the specified
external volume group (ExG)
does not exist. Check the
setting.
A virtual parity group (VPG)
cannot be allocated to the
external volume group (ExG).
690110610
0WThe area to allocate LDEVs is
insufficient. Check the setting.
Cannot allocate all LDEVs.690120610
0WThe number of SSIDs that can
be used in the SLPR may be
insufficient. Check the setting.
SSID cannot be allocated.690130610
5iCheck all items in the [Set
External Volume Parameter]
dialog box and click [OK].
The selected volumes include
an external volume that the
external volume parameter is
already set. Set the
configuration in the following
[External Volume Parameter]
dialog box.
690260610
100 Remote Web Console for Storage System Messages and Error Codes