HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96014, September 2007)

Part
Code
Error
Number
Error Message
Recommended Action
Severity
Level
Failure
Level
8105
1184
The port information is
inconsistent with PCB mode
information.
Please correct the port
information or the PCB
mode
information.
W
0
8105 1190
To dene a path to the
volume from an iSCSI
port, the volume must be
read/write-enabled and
also usable
as an S-VOL
(secondary volume).
Correct the settings, then
retry the operation.
E
6
8105 1193
You cannot a
dd
paths to
Continuous
Access/Business
Copy/Cross
-system Copy
pair volum
es.
Please corr
ect the settings,
then
retry.
E
6
8105 1198
Since a path is dened to
an
external LU, you can not
set
high-speed mode.
Please correct the settings,
then
retry.
E
6
8105 1201
The selection of High Speed
mode/MIX mode is invalid.
The specied port cannot
be changed to High Speed
mode/MIX mode.
Change the parameter to a
path where the High Speed
mode/MIX mode can be
set, then retry the operation.
E 5
8105 1203
High Spe
ed
mode/MIX
mode
was specied.
However, there are
addresses to which High
Speed m
ode/MIX mode
canno
tbeset in theFibre
Addre
sses
of the specied
port
s.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
8105
1204
High Speed mode/MIX
mode
was specied.
However, there are
topologies to which
High Speed mode/MIX
mode
cannot be set in the
topologies of the specied
ports.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
8105 1350
Add path to the initiator
port failed.
The port you are trying to
set
is for Fibre Continuous
Access. You must change
the
attribute when addi ng
apath. Attribute(TarGet or
RCU TarGet)
E
2
8105 1351
The high-speed or
initiator/external mix
mode
cannot be set to the
specied port because of
the
attribute of the port.
Cannot set to high-speed
mode
because the
port attributes are
mixed, or cannot set to
internal/external mix mode
because the combination of
port attributes is different.
Check the port attributes,
then
retry the operation.
E
6
348
HP
StorageWorks XP Remote Web Console for Storage System Messages and Error Codes