HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96014, September 2007)
Part
Code
Error
Number
Error Messag e
Recommended Ac tion
Severity
Level
Failure
Level
8105 1133
Failed to set the host mode
because the number of
host modes exceeds the
maximum that can be set in
aport.
The Configuration
information has been
already changed.
Please check the settings
and request the setting of the
configuration information
again.
E
6
8105
1134
Failed to set the path
because the number of
paths exceeds the maximum
that can be set in a port.
The Configuration
information has been
already changed.
Please check the settings
and request the setting of the
configuration information
again.
E
6
8105 1135
An error occurred. If this
problem persists, please call
technical support.
When PORT information
(Fibre Address/Fibre
Topology/Channel Speed)
is set, multiple change
instructions are set to the
same PORT.The errordoes
not
occur normally because
it
is guarded in the screen.
In the
unlikely event that
this error occurs, contact
technical support.
E
2
8105 1136
An error occurred. If this
problem persists, please call
technical support.
When CHA high-speed
mode is set, multiple change
instructions are set to the
same PORT.The errordoes
not
occur normally because
it
is guarded in the screen.
In the
unlikely event that
this error occurs, contact
technical support.
E
2
8105 1137
Failed to from a LUSE
volume because the number
of LUSE volumesexceedsthe
maximum that can be set in
adiskarray subsystem.
The Configuration
information has been
already changed.
Please check the settings
and request the setting of the
configuration information
again.
E
6
8
105
1140
N
othing is set. Create a
s
etting an d then execute it.
P
lease release the Port
G
roup setting.
W 6
8105 1170
The volume cannot be
configured as a command
device because the volume
does not have Read/Write
attribute.
Please connect settings, then
retry.
E
6
8105 1181
The specified path cannot be
added, because the volume
is
used by a Continuous
Access pair.
Correct the specified
contents, and request again.
E
6
8105 1183
The port information is
inconsistent with PCB mode
information.
Please correct the port
information or the PCB
mode information.
W 0
XP24000/XP20000 Remote Web Console Error Codes
347