HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96014, September 2007)
Part
Code
Error
Number
Error Message
Recommended Action
Severity
Level
Failure
Level
7105 58351
TheQuick Restorecommand
has
been rejected, because
the
specified pair is
composed of internal
and external volumes, and
also used as a
Universal
Replicator for Mainframe
pair.
Stop using the specified
pair for Universal Replicator
forMainframe,or specify a
different pair, then retry the
operation.
i
0
7105 58356
The command was rejected,
because the specified
volume was used by
Universal Replicator for
Mainframe and TrueCopy
for Mainframe.
To continue the operation,
release the Universal
Replicator for Mainframe
pair or the
TrueCopy for
Mainframe pair, an d retry
the
operation.
i
0
7105
58451
The storage system is in
internal process. Please
retry the operation.
If the problem persists
despite retrying, call
technical support.
W
0
7105 58518
The operation failed,
because th e XP Snapshot
pair(s) existed.
To continue the operation,
delete all XP Snapshot
pair(s) a nd retry.
i
0
7105 58519
The operation failed,
because th e XP Snapshot
pair(s) existed.
To continue the operation,
delete all XP Snapshot
pair(s) a nd retry.
i
0
7105 58520
The operation failed,
because different versions of
microcodes coexisted in the
storage system.
Replace the microcode, then
retry the operation.
E
2
7105 58533
The operation failed,
because the specified S-VOL
was a journal volume.
Release the journal volume
setting or specify another
volume.
W
2
7105
58534
The operation failed,
because the specified T-VOL
was a journal volume.
Release the journal volume
setting or specify another
volume.
W
2
7105 58535
The r
eserve volume setting
failed because the specified
volume was a journal
volume.
Release the journal volume
setting or specify another
volume.
W
2
7105 58536
The operation failed
because the specified
T-VOL was a data volume
of Universal Replicator
for Mainframe. Check
the
requirements for using
thevolumewithUniversal
Replicator for Mainframe.
Check the requirements
for using thevolumewith
Universal Replicator for
Mainframe.
W
5
7105 5857 2
An error occurred while
connecting to the subsystem.
Please wait for a while, and
then
retry the operation.
If thesameproblem
persists despite retrying,
call
technical support.
E
6
7105 5857 3
This function is not
supported.
Check whether the
DKCMAIN microcode
version and the SVP
micro code version are
mismatched.
E
3
334
HP
StorageWorks XP Remote Web Console for Storage System Messages and Error Codes