HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96014, September 2007)
Part
Code
Error
Number
Error Message
Recommended Action
Severity
Level
Failure
Level
7005
58484
The o peration cannot be
performed, because the
specified reserved volume is
a
pool volume.
Release the pool volume or
select another volume.
W
5
7005 58492
The Pairsplit-S operation
has
failed. Check the
configuration.
Refresh the window and
check whether the pair
exists.
W
5
7005
58493
The PCB requi
red for this
operation is
not mounted.
Check the su
bsystem
configurati
on.
Mount the required PCB,
then
retry the operation.
W
5
7 005 585 20
The operation failed,
because different versions of
microcodes coexisted in the
storage system.
Replace the microcode, then
retry the operation.
E
2
7 005 58533
The operation failed,
because the specified P-VOL
was a journal volume.
Release the journal volume
setting or specify another
volume.
W 2
7005
58534
The opera
tion failed,
because t
he
specified S-VOL
was a jour
nal
volume.
Release the journal volume
setting or specify another
volume.
W
2
7 005 58535
The reserve volume setting
failed because the specified
volume was a journal
volume.
Release the journal volume
setting or specify another
volume.
W
2
7 005 58536
The operation failed
because the specified
S-VOL was a data volume of
Continuous Access Journal.
Check the requirements
forusing thevolumewith
Continuous Access Journal.
Check the requirements
for using thevolumewith
Continuous Access Journal.
W
5
7 005 5857 2
An error occurred while
connecting to the subsystem.
Ple
ase wait for a while, and
the
n
retry the operation.
If th
is
problem persists, call
tec
hnical support.
E
6
7 005 5857 3
This function is not
supported.
Check whether the
DKCMAIN microcode
version and the SVP
micro code version are
mismatched.
E
3
7 005 58574
An error occurred while
connecting to the subsystem.
Please wait for a while, and
then
retry the operation.
If this problem persists, call
technical support.
E
6
7 005 58575
An error occurred while
connecting to the subsystem.
Please wait for a while, and
then
retry the operation.
If this problem persists, call
technical support.
E
6
7 005 58576
A communication time-out
error occurred i n the storage
system. Please wait for a
while, and then retry the
operation.
If this problem persists, call
technical support.
E
6
316
HP