HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96014, September 2007)

Part
Code
Error
Number
Error Message
Recommended Action
Severity
Level
Failure
Level
7005 58001
The operation of the L2
pair failed because the
L1
pair was in COPY(SP)
status, PSUS(SP) status or
COPY(RS-R) status.
Wait until the L1 pair status
changes to PSUS or PAIR,
then
retry the operation.
i
0
7005 58002
TheQuick Restorecommand
has
been rejected because
the
specied pair is
composed of a normal
volume and a customized
volume (CV).
Thequick restoreoperation
cannot be performed when
the pair is composed of
anormalvolumeand a
customized volume (CV).
Select a different pair.
i
0
7005 58003
The command has been
rejected because a
Continuous Access pair
exists in the same subsystem
frame.
To continue the operation,
delete the Continuous
Access pair.
i
0
7005 58004
The command has been
rejected because the issued
request is an op eration that
cannot
be performed with
a
volume that can be used
from either the m ainframe
or
open-system hosts.
The requested operation
cannot
be performed.
Check the status of the
specied volume.
i
0
7005 58259
TheQuick Restorecommand
has
been rejected, because
the
specied pair is
composed of internal
and external volumes, and
also
used as a Continuous
Access pair.
Stop using the specied pair
for Continuous Access, or
specify a different pair, then
retry the operation.
i
0
70
05
58
260
The
Reverse Copy or Quick
Res
tore command has been
rej
ected, because the P-VOL
is
also used as the P-VOL of
aC
ontinuous Access pair
wh
ose status is not Suspend.
Change the status of the
Continuous Access pair,
then
retry the operation.
i
0
7005 58261
The Reverse Copy or Quick
Restore command has been
rejected, because the P-VOL
is
used as the S-VOL of a
Continuous Access pair.
Please delete the Continuous
Access pair or operate other
pairs.
i
0
7005 58262
A pair cannot be created
because shared memory
for differential tables is
insufcient.
Please add sufcient shared
memory to create a pair.
i
0
7 005 58299
The operation failed
because the specied
P-VOL was a d ata volume of
Continuous Access Journal.
Check the requirements
forusing thevolumewith
Continuous Access Journal.
Check the requirements
for using thevolumewith
Continuous Access Journal.
W
5
7 005 58300
The operation failed
because the specied
S-VOL was a data volume of
Continuous Access Journal.
Release the Continuous
Access Journal setting or
specify another volume.
W
5
314