HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96014, September 2007)

Part
Code
Error
Number
Error Message
Recommended Action
Severity
Level
Failure
Level
6505 58039
The specied volume is
already used as a journal
volume or adatavolume.
Specify another volume.
i
0
6505
58040
An internal error occurred.
Please check the SSB log,
then
call technical support.
E
4
6505 58064
Too many requests. Please
reduce the number of
requests to be processed at
one
time. After that, please
retry the operation.
Please reduc
ethe number
of
requests t
o
be processed
at one
time. T
hen
retry the
operation.
i
0
6505 58065
Invalid parameter (LDEV
number).
Check the specied LDEV
number.
i
0
6505 58066
Invalid pa rameter (Journal
Group number).
Check the specied journal
group number.
i
0
6505 5806 7
Invalid parameter (Mirror
ID).
Check the specied mirror
ID.
i
0
6505 58068
Invalid pa rameter (Journal
Control).
Check the specied JNL
Control parameter.
i
0
6505 58069
Invalid parameter (Suspend
Condition-Journal Full).
Check the specied Suspend
Condition parameter.
i
0
6505 5807 0
Invalid p
arameter (Suspend
Conditio
n-Master Journal
Failure
).
Check the specied Suspend
Condition parameter.
i
0
6505 58071
Invalid parameter (Suspend
Condition-Restore Journal
Failure).
Check the specied Suspend
Condition parameter.
i
0
6505 5807 2
The pair status has not
changed yet. Check
the
conguration of the
subsystems and the status
of lines connecting the
subsystems, and then check
whether the status of the
Continuous Access pair is
changed.
The current conguration
of
the storage systems and
the
current status of lines
connecting the storage
systems may not satisfy
the
operating conditions.
Check the conguration of
the
storage systems and the
status of lines connecting
the storage systems, then
check whether the status of
the
Continuous Access pair
is
changed.
W 4
6505 5807 3
The subsystem is busy . W ait
for a while, and then retry
the
operation.
If thesameerror occurs
despite retrying, call
technical support.
W
0
6505 5807 5
The specied serial number
is
incorrect.
Check the specied serial
number.
i
0
6505 58078
The specied volume does
not exist or is unusable.
Check the status of the
specied volume.
i
0
25 2
HP
StorageWorks XP Remote Web Console for Storage System Messages and Error Codes