HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96014, September 2007)

Part
Code
Error
Number
Error Messag e
Recommended Ac tion
Severity
Level
Failure
Level
6005
89 43
The specied volume
or other
volume(s) of
thesamegroup in the
RCU is being changed to
Simplex/Suspend status.
Retry the operation a few
minutes later.
Refresh the window a few
minutes later and check
the status of the specied
volume and other volume(s)
of the sa m e group in the
RCU. If it is p ossible to
perform operations on
the volume(s), retry the
operation.
i
4
6005
89 44
The specied R-VOL is not
available according to
the
attribute of the R-VOL
changed by Data Retention
Utility.
Check the status of the
specied R-VOL.
i
4
6005
89 45
At least one of the following
is
invalid:
M-VOL parameters (CU
number, Port, GID, LUN)
SSID or CU number of
the
RCU
R-VOL parameters (Por t,
GID, LUN)
Verify whether the
parameters of M-VOL,
for example, CU number,
port, GID and LUN, are
supported with the RCU
microcode program version
or
not. V
erify whether the
SSID an
d
CU number of
RCU and
the parameters of
R-VOL
,
for example, Port,
GID
an
dLUN,are correct
or
not
.
And then, retry the
oper
ationwiththe correct
para
meters.
W 4
6005 8947
The external volume that
is mapped to an internal
volume is c onnected to the
port.
Release the setting of the
external volume, and retry
the operation.
i
4
6005 8948
The specied port is
receiving I/O requests.
Stop I/O op erations, and
retry.
i
4
60
05
89 49
An internal error occurred.
Ple
ase call technical
su
pport.
E
4
6005 8950
An internal error occurred.
Please call technical
support.
E
4
6005 897 3
Failed to create a pair,
because the specied R-VOL
is
used for Cross-system
Copy.
Check the status of the
specied R-VOL.
i
4
6005
8974
Failed to create a pair,
because the specied
M-VOL is path-dened from
the
iSCSI port.
Check the status of the
specied M-VOL.
i
4
6005 8975
Failed to create a pair,
because the specied R-VOL
is path-dened from the
iSC SI port.
Check the status of the
specied R-VOL.
i
4
6005 8976
A pair cannot be created,
because the specied
M-VOL is an external
volume.
Check the status of the
specied M-VOL.
i
4
XP24000/XP20000 Remote Web Console Error Codes