HP StorageWorks XP24000/XP20000 Remote Web Console Error Codes (AE131-96014, September 2007)
Part
Code
Error
Number
Error Messag e
Recommended Ac tion
Severity
Level
Failure
Level
1005 2032
Communication busy.
Please retry later.
Please retry later .
E
3
1005 2082
Processing is disabled
because the host is mounted
or thedeviceisreserved.
The host is mounted or
thedeviceisreserved.
Please unmount the host
and
cancel reservation of
the device. If the host is an
AIX host, unmount the host,
and
execute the varyoffvg
command.
E
6
1005 2083
The subsys
tem
status is
invalid. P
lease call technical
support.
Check the D
KC status and
the curren
tstatusof the
configurat
ion setting. If
necessar
y, re-execute the
setting o
peration.
E
2
1005
2084
The subsystem status is
invalid. Please call technical
support.
Check the DKC status and
the current status of the
configuration setting. If
necessary, re-execute the
setting operation.
E
2
1005 2097
The host specified by the
WWNisperformingI/O
operations.
Please stop executing I/Os,
then retry the operation.
E
6
1005 2098
The op
eration cannot be
perfo
rmed, because the
SVP mi
crocode version does
not
ma
tch the DKCMAIN
(sub
system) microcode
vers
ion.
Please call technical
support, when the same
problem persists.
E
6
1005 2099
The operation cannot be
performed, because an
inoperative MP exists.
Wait a while, then retry
the operation. If the same
problem persists. Please call
technical support.
E
6
1005 2100
An error occurred while
connecting to the storage
system. The configuration
may be inconsistent. Please
select [All Refresh] and
refresh the configuration.
Click [ All Refresh] and
refresh the configuration.
E
2
1005 2500
To define a path to the
volume from an iSCSI
port, the volume must be
read/write-enabled and
also usable as an S-VOL
(secondary volume).
Correct the settings, then
retry the operation.
E
6
1005 2501
The volume cannot be
configured as a command
device because the volume
does not have Read/Write
attribute.
Please correct settings, then
retry.
E
6
1005 2502
The LUs cannot be combined
or
released because
the
volumes don't have
Read/W rite attribute.
Please correct settings, then
retry.
E
6
XP24000/XP20000 Remote Web Console Error Codes
117