HP StorageWorks XP24000/XP20000 for FlashCopy Mirroring Software User Guide (T5240-96012, May 2011)
Table 55 ANTRQST Macro Command Parameters (in Version 2)
DescriptionValueParameterCommand
Specifies the copy source
extent (copy range) by
setting the starting and
ending addresses of the
source and target with
CCHH (cylinder and head
numbers). Up to 32 extents
can be specified. When
SRCEXTENTS is not
specified, the data on all the
tracks is copied. Note that
you cannot specify this
parameter if you specify YES
for the INCREMENTAL
parameter.
Copy source extent (copy
range)
SRCEXTENTSREQUEST=FCESTABLISH
Specifies the copy target
extent (copy range) by
setting the starting and
ending addresses of the
source and target with
CCHH (cylinder and head
numbers). Up to 32 extents
can be specified. When
TGTEXTENTS is not
specified, the data on all the
tracks is copied. Note that
you cannot specify this
parameter if you specify YES
for the INCREMENTAL
parameter.
Copy target extent (copy
range)
TGTEXTENTS
Establishing Version 2 Relationships while Suspending Write Operations to S-VOLs
When you establish Version 2 relationships with the FCESTABL command while suspending the
write operations to the S-VOLs to keep the data consistency, the ACTION parameter (see “Parameters
for the FCESTABL Command (Version 2/Suspending Write Operations to S-VOLs)” (page 106)) is
available in addition to the parameters in “Parameters for the FCESTABL Command (Version
2/Volume Copying)” (page 84) and “Parameters for the FCESTABL Command (Version 2/Dataset
Copying)” (page 103).
Table 56 Parameters for the FCESTABL Command (Version 2/Suspending Write Operations to
S-VOLs)
DescriptionValueParameter
Suspend the write operations from the
host to the S-VOLs. Note that if you
establish a relationship specifying
extents, the ACTION parameter will
suspend the write operation to the
whole volume.
FREEZEACTION
“FCESTABL Command (Version 2/ACTION Specified)” (page 107) shows an example of how to
use the FCESTABL command to suspend the write operation to an S-VOL when you establish a
Version 2 relationship. In this example, the FCESTABL command establishes a relationship for the
volumes (devices) numbered 4202 and 4203, and at the same time, suspends the write operation
from the host to the source device numbered 4202.