HP StorageWorks XP24000/XP20000 for Compatible Extended Remote Copy (XRC) Software User's Guide (T5238-96001, March 2008)

operation mode setting of Compatible XRC in the Change Option dialog box (see
Figure 13 on page 33).
Table 7 HP Compatible XRC in Conventional Models and XP24000/XP20000 Disk Arrays
Option Settings of XRC in
XP24000/XP20000 Disk Array
storage systems
Operation Modes of HP Compatible XRC in
Conventional Model
118989786856145
Block Option: Cache Level
Do not Block (Volume Level): Disable
Level 1 Sleep: Enable
OffOff
Block Option: Cache Level
Do not Block (Volume Level): Enable
Level 1 Sleep: Enable (see
Note
)
OnOff
Block Option: Cache Level
Do not Block (Volume Level): Disable
Level 1 Sleep: Disable
OffOn
Block Option: Volume Level
Do not Block (Volume Level): Enable
Level 1 Sleep: Disable
OnOn
Level 2 Threshold: 50%OffOff
Level 2 Threshold: 60%OnOff
Level 2 Threshold: 40%OffOn
Level 2 Threshold: 70%OnOn
Sleep Time: 100 msOff
Sleep Time: 10 msOn
Level 2 Suspend: DisableOff
Level 2 Suspend: EnableOn
Level 1 SIM: DisableOff
Level 1 SIM: EnableOn
Note
: Level 1 Sleep is performed on a volume in which a threshold specified by SDM is
enabled (Block option). Level 1 Sleep is not performed on the volume for which Do not Block
(Volume Level) is specified.
The behavior of the XP24000/XP20000 Disk Array storage systems, that are affected by
option settings in the Change Option dialog box (Figure 13 on page 33), is also affected by
XP24000/XP20000 for Compatible Extended Remote Copy (XRC) Software User's Guide 25