HP StorageWorks XP24000/XP20000 Audit Log User and Reference Guide (AE131-96013, September 2007)

user-name,xx,YYYY/MM/DD,HH:MM:SS:xx, 00:00,[Information],Threshold Value,Alter,Normal end,,,Seq.=xxxxx
+Type=7days
+{Mechanical error(Recovered,Unrecd.),Media error(Recovered,Unrecd.),
Read/Write error(Recovered,Unrecd.),Drive I/F error(Recovered,Unrecd.),
Controller hardware error(Recovered,Unrecd.),FC I/F error Port 0(Unrecd.),
FC I/F error Port 1(Unrecd.),Prot 0 error(Unrecd.),Port 1 error(Unrecd.)}
={(150,60),(0,15),(150,30),(150,6),(150,6),6,6,12,12}
++PDEV=[HDDR00-01,HDDR00-02,(snip)],Num. of PDEVs=1152
Example 2
user-name,xx,YYYY/MM/DD,HH:MM:SS:xx, 00:00,[Information],Threshold Value,Error Reset,Normal end,,,Seq.=xxxxx
+PDEV=HDDR00-01
[Information]
Information function
Threshold Value
Threshold Value operation
Alter and Error Reset
Alter is the selected parameter for example 1 and Error Reset is the selected parameter for example
2. This operation uses the parameters shown in the following table.
Table 31 Parameters: Threshold Value Operation
DescriptionParameter
Change the threshold of failed PDEV (physical device).Alter
Indicates Error Reset.Error Reset
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 32 Detailed Info: ORM Value Operation (Example 1)
DescriptionItem
The period of time to acquire the result of threshold diagnosis using the read diagnosis
function.
Type
7days: 7 days, Total: Every operating days
The threshold of Mechanical error.Mechanical error
(Recovered,Unrecd.)
The threshold of Media error.Media error
(Recovered,Unrecd.)
XP24000/XP20000 Audit Log User and Reference Guide 75