HP StorageWorks XP24000/XP20000 Audit Log User and Reference Guide (AE131-96013, September 2007)
Journal-Option Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[UR],Journal-Option,,Normal end,Seq.=xxxxx
+{LDKC,JNLG,MetaData Ratio,Extent,Data Overflow Watch(s),Inflow Control,Copy Pace,
Timer Type,
Path Watch Time,Forward Path Watch Time,Use of Cache,Speed of Line(Mbps),Delta
resync Failure,Result}=
-{0x00,0x00,32,32,20,No,150,Local,30(min.),Yes,Not Use,256,Entire,Normal end},
(snip),
{0x00,0x02,32,32,20,No,150,Local,30(min.),Yes,Not Use,256,Entire,Normal end},
Num. of JNL Grps=3
[UR]
Universal Replicator for Mainframe function (for IBM z/OS)
Journal-Option
Journal-Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 209 Detailed Info: Journal-Option Operation
DescriptionItem
The journal group's LDKC number.LDKC
The journal group number.JNLG
The ratio of the metadata to the journal data.MetaData Ratio
When the ratio is 1:32, the number for MetaData Ratio is 32.
The number of extents.Extent
The overflow watch time of the metadata or journal data. The unit is second.Data Overflow
Watch(s)
Indicates whether or not inflow control is executed. Yes: Controlled, No: Not controlledInflow Control
The speed of initial copy. 150: Low speed, 500: Medium speed, 1500: High speedCopy Pace
The timer type. System: System timer, Local: Local timer, None: No timerTimer Type
The path blockade watch period set.Path Watch Time
The unit is minutes, hours or days.
If it is set to 30 minutes, it will be 30(min.).
Indicates whether to transfer the path blockade watch period set to the master journal
group to the restore journal group. Yes: Transfer, No: Do Not Transfer.
Forward Path
Watch Time
XP24000/XP20000 Audit Log User and Reference Guide 237