HP StorageWorks XP24000/XP20000 Audit Log User and Reference Guide (AE131-96013, September 2007)

Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 153 Detailed Info: Change RCU Option
DescriptionItem
Indicates a serial number of the RCU device where the RCU option setting is changed.S/N
The LDKC number of the paired LDKC.LDKC
The RCU path group ID where the RCU optional setting is changed. When the path
group ID is default setting, Default is output.
Path Gr. ID
The controller ID of the RCU where the optional setting is changed.Controller ID
Indicates SSID of the RCU where the optional setting is changed.SSID
The minimum number of paths after change.Min. Path
The value of RIO MIH (Remote I/O Missing Interrupt Handler) timer (wait time until data
copy from MCU to RCU is completed). The unit represents seconds.
MIH Time(s)
The round-trip response time (delay time for round-trip remote I/O) after change. The
unit is in milliseconds. This value is output when HP XP Continuous Access Software or
TrueCopy for Mainframe is used.
Round Trip
Time(ms)
The incident of RCU after change. This value is output only when TrueCopy for Mainframe
is used.
Incident
only to RCU host” or “to any host” is output.
Indicates whether CGROUP (FREEZE/RUN) PPRC TSO command support is enabled or
disabled. This value is output only when TrueCopy for Mainframe is used.
FREEZE
Enable or Disable is output.
The number of port pairs changed.Num. of Port Pairs
Delete Path Operation
Example 1 (CU Free is used)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[RCU],Delete Path,,Normal end,,,Seq.=xxxxx
+{S/N,LDKC,Path Gr. ID,Controller ID}={99999,0x00,Default,4}
++{MCU Port,RCU Port}=[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},{5G,7G},{1H,3H},{5H,7H}],
Num. of Port Pairs=8
Example 2 (CU Free is not used)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[RCU],Delete Path,,Normal end,,,Seq.=xxxxx
+{S/N,LDKC,SSID,Controller ID}={99999,0x00,0x0004,4}
Remote Control Unit (RCU) Function178