HP StorageWorks XP24000/XP20000 Audit Log User and Reference Guide (AE131-96013, September 2007)

DescriptionItem
The CU number of the connected CU.MCU
The CU number of the paired CU.RCU
The SSID of the registered RCU.SSID
The port number of MCU.MCU Port
The port number of the registered RCU.RCU Port
The number of set minimum paths.Min. Path
The value of set RIO MIH (Remote I/O Missing Interrupt Handler) timer (wait time until
data copy from MCU to RCU is completed). The unit is second.
MIH Time(s)
The round-trip response time set (delay time for round-trip remote I/O). The unit is
millisecond. This value is output when HP XP Continuous Access Software or TrueCopy
for Mainframe is used.
Round Trip
Time(ms)
The set incident of the RCU. This value is output only when TrueCopy for Mainframe is
used.
Incident
only to RCU host” or “to any host” is output.
Indicates whether CGROUP (FREEZE/RUN) PPRC TSO command support is enabled or
disabled. This value is output only when TrueCopy for Mainframe is used.
FREEZE
Enable or Disable is output.
The number of port pairs set.Num. of Port Pairs
Change RCU Option Operation
Example 1 (CU Free is used)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[RCU],Change RCU Option,,Normal end,,,Seq.=xxxxx
+{S/N,LDKC,Path Gr. ID,Controller ID,Min. Path,MIH Time(s), Round Trip Time(ms),Incident,
FREEZE}={99999,0x00,Default,4,08,015,001,only to RCU host,Disable}
Example 2 (CU Free is not used)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[RCU],Change RCU Option,,Normal end,,,Seq.=xxxxx
+{S/N,LDKC,SSID,Controller ID,Min. Path,MIH Time(s), Round Trip Time(ms),Incident,
FREEZE}={99999,0x00,0x0004,4,08,015,001,only to RCU host,Disable}
[RCU]
Remote Control Unit function
Change RCU Option
Change Remote Control Unit Option operation
Normal end
The operation has ended normally.
XP24000/XP20000 Audit Log User and Reference Guide 177