HP StorageWorks XP24000/XP20000 Audit Log User and Reference Guide (AE131-96013, September 2007)

user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Maintenance], Replace,,Normal end,,,Seq.=xxxxx
+PDEV=HDD00-01
+Copy=Restore Data
+Diagnosis=Skip,Micro Program=Skip
Example 5 ( Easy-replace of PDEV (physical device))
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Maintenance], Replace,Easy-Replace,Normal end,Seq.=xxxxx
+PDEV={HDDR03-01},Num. of PDEV=1
Example 6 (replacing a fibre switch)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Maintenance], Replace,,Normal end,,,Seq.=xxxxx
+FSW=[FSWR04-LL,FSWR05-LL],Num. of FSWs=2
[Maintenance]
Maintenance function
Replace
Replace operation
Easy-Replace
Easy-Replace is the parameter output when easy replacing a PDEV.
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 133 Detailed Info: Replace Operation
DescriptionItem
The name of the parts (EPOSW, PCICON, PCIADP, DKCPANEL, PSxx, PS-xx, BATTERY-xx,
ACBOX-x, FAN-xx, TH-xx, SSVP/MN, SVP, HDDFANxx-x, BATTERY-Uxxx, BATREG-x,
FUSE-xxx, ACBOX-Uxxx, DKUPS-xxx, SVRxxx-x, SVRxxx-Ex, EXTADP, BATTERY-SBx,
SBADP, or LEDPNLxx-x) specified to be replaced.
Parts name
The port which Small Form-Factor Pluggable (SFP)s are inserted.SFP
The number of inserted Small Form-Factor Pluggable (SFP)s.Num.of SFPs
The mounting location of the PCB, (Channel Adapter (CHA), Disk Adapter (DKA), cache
memory, CM, SM, cache switch, MIX or BASE) to be replaced.
PCB
When replacing multiple PCBs and some of the PCBs to be replaced had failures, the
mounting locations of the failed PCBs are indicated. In such case, Warning is output as
the result of the process.
Failed
NOTE:
This information is not output when there are no failed PCBs.
Maintenance Function158