Table 49 Change Async Option
DescriptionItem
The CLPR number.CLPR
The value set to the pending update data rate.Rate (%)
The value set to the I/O Delay Start value (the threshold that the inflow control of
asynchronous copy starts).
Delay Start (%)
The value set to the I/O Delay Increase value (the threshold that the inflow control of
asynchronous copy increases).
Delay Increase (%)
Change CTG Option Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Cnt Ac],Change CTG Option,,Normal end,,,Seq.=xxxxx
+{LDKC,CTG, Offloading(s),Inflow Control,Copy Pending(min.),RCU Ready(min.)}=
{0x00,0x00,090,Enable,05,05}
[Cnt Ac]
HP XP Continuous Access Software function
Change CTG Option
Change Consistency Group Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 50 (page 66).
Table 50 Change CTG Option
DescriptionItem
The LDKC number.LDKC
The consistency group number of the consistency group (CT group) where the option is
changed.
CTG
The value set to the monitoring time of transfer to the side file. The unit is second.Offloading(s)
Indicates whether the inflow control to the cache is enabled or disabled.
Enable: Setting is enabled, Disable: Setting is disabled
Inflow Control
The setting value for Time Out (Copy Pending). The unit is minute. When Time Out (Copy
Pending) is set to 0 (zero), None is output.
Copy Pending (min.)
The setting value for Time Out (RCU ready). The unit is minute. When Time Out (RCU
ready) is set to 0 (zero), None is output.
RCU Ready (min.)
Change Option Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Cnt Ac], Change Option,,Normal end,,,Seq.=xxxxx
+{ Parallel Initial Copy,Path Blockade Watch(s),Path Blockade SIM Watch(s),
Service SIM,Parallel Initial Copy(CU)}={128,45,70,Not Report,Disable}
+{LDKC,CU,Service SIM,PPRC Support,SCP Time(s), Parallel Initial Copy(CU)}=
-{0x00,0x00,Not Report,Yes,600,4},{0x00,0x01,Not Report,Yes,600,4},{0x00,0x02,
Not Report,
Yes,600,4},{0x00,0x03,Not Report,Yes,600,4},{0x00,0x04,Not Report,Yes,600,4},
(snip)
-(snip), Num. of CUs=255
[Cnt Ac]
HP XP Continuous Access Software function
66 XP Continuous Access Software Function