HP StorageWorks XP24000/XP20000 Audit Log Reference Guide (AE131-96085, May 2011)

Table 271 Edit-EXCTG Operation (continued)
DescriptionItem
The controller IDCTRLID
The LDKC, CU, and LDEV numbers of the remote command deviceCmd.Dev.
(LDKC:CU:LDEV)
The result of the operation
Normal end: normal end, Error(xxxx-yyyyy): abnormal end
xxxx: part code, yyyyy: error code
Result
The number of extended consistency groups for which the configuration has been
changed
Num. of EXCTGs
Journal-Option Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[UR],Journal-Option,,Normal end,Seq.=xxxxx
+{LDKC,JNLG,MetaData Ratio,Extent,Data Overflow Watch(s),Inflow Control,Copy Pace,
Timer Type,
Path Watch Time,Forward Path Watch Time,Use of Cache,Speed of Line(Mbps),Delta
resync Failure,Result}=
-{0x00,0x00,32,32,20,No,150,Local,30(min.),Yes,Not Use,256,Entire,Normal end},
(snip),
{0x00,0x02,32,32,20,No,150,Local,30(min.),Yes,Not Use,256,Entire,Normal end},
Num. of JNL Grps=3
[UR]
Universal Replicator for Mainframe function (for IBM z/OS)
Journal-Option
Journal-Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 272 (page 221).
Table 272 Journal-Option Operation
DescriptionItem
The journal group's LDKC number.LDKC
The journal group number.JNLG
The ratio of the metadata to the journal data.
When the ratio is 1:32, the number for MetaData Ratio is 32.
MetaData Ratio
The number of extents.Extent
The overflow watch time of the metadata or journal data. The unit is second.Data Overflow
Watch(s)
Indicates whether or not inflow control is executed. Yes: Controlled, No: Not controlledInflow Control
The speed of initial copy. 150: Low speed, 500: Medium speed, 1500: High speedCopy Pace
The timer type. System: System timer, Local: Local timer, None: No timerTimer Type
The path blockade watch period set.
The unit is minutes, hours or days.
If it is set to 30 minutes, it will be 30 (min.).
Path Watch Time
Journal-Option Operation 221