HP StorageWorks XP24000/XP20000 Audit Log Reference Guide (AE131-96085, May 2011)

Change Async Option Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,[TC],Change Async Option,,Normal end,,,Seq.=xxxxxx
+{CLPR,Rate(%)}={00,050}
[TC]
TrueCopy for Mainframe function (for IBM z/OS)
Change Async Option
Change Async Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 257 (page 210).
Table 257 Change Async Option
DescriptionItem
The CLPR number.CLPR
The specified pending update data rate.Rate (%)
Change CTG Option Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[TC], Change CTG Option,,Normal end,,,Seq.=xxxxx
+{LDKC,CTG, Offloading(min.),Inflow Control,Copy Pending(min.),RCU Ready(min.),
Timer Type}=
{0x00,0x00,090,Enable,05,05,System}
[TC]
TrueCopy for Mainframe function (for IBM z/OS)
Change CTG Option
Change Consistency Group Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 258 (page 210).
Table 258 Change CTG Option Operation
DescriptionItem
The LDKC number.LDKC
The consistency group number of the consistency group (CT group) that the option is
changed.
CTG
The value set to the offloading timer of the sidefile. The unit is minute.Offloading (min.)
Indicates whether the inflow control to the cache is enabled or disabled.
Enable: Setting is enabled, Disable: Setting is disabled
Inflow Control
The setting value for Time Out (Copy Pending). The unit is minute. When Time Out (Copy
Pending) is set to 0 (zero), None is output.
Copy Pending (min.)
210 TC for Mainframe Function