HP StorageWorks XP24000/XP20000 Audit Log Reference Guide (AE131-96085, May 2011)

Table 223 Set Prio WWN Operation (continued)
DescriptionItem
The type of rate used for the upper limit control.
IOPS: I/O rate, KB/s: Transfer rate.
This value is not output when the attribute is set to prioritized WWN.
Mode
The number of WWNs of the host bus adapters that the setting is changed.Num. of WWNs
Indicates WWN of the host bus adapter. WWN is a 16-digit number in the hexadecimal
format.
WWN
Update Port WWN Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Perf Ctrl],Update Port WWN,,Normal end,,,
Seq.=xxxxx +{Mode,WWN,PPC Name,Priority}=[{Add WWN,0xXXXXXXXXXXXXXXXX,XXXXXXXXXXXXXXXX,
Non-Prio}, ++Port=[1A,3A],Num. of Ports=2],Num. of WWNs=1
[Perf Ctrl]
XP Performance Control (Perf Ctrl) function
Update Port WWN
Update Port WWN operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 224 (page 184).
Table 224 Update Port WWN Operation
DescriptionItem
The operation executed.
Add WWN: New registration of WWN (the host bus adapter is subject to monitoring)
Delete WWN: Deletion of WWN (the host bus adapter is not subject to monitoring)
Mode
Indicates WWN of the host bus adapter registered or deleted. WWN is a 16-digit number
in the hexadecimal format.
WWN
The Perf Ctrl name of the host bus adapter registered or deleted.PPC Name
The attribute of the registered host bus adapter.
Prio: Prioritized WWN, Non-Prio: Non-prioritized WWN
This value is output only when the host bus adapter (WWN) is registered.
Priority
The name of the port to which the host bus adapter is registered.Port
The number of ports to which the host bus adapter is registered.Num. of Ports
The number of WWNs of the registered or deleted host bus adapters.Num. of WWNs
Update XP Performance Control Group (PerfCtrlGrp) Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Perf Ctrl],Update PerfCtrlGrp,,Normal end,,,
Seq.=xxxxx +{UpdateMode,PPC Group,Priority,Upper Limit,Mode}=[{Add WWN,XXXXXXXXXXXXXXXX,
Non-Prio,XXXXXXXX,IOPS},++WWN=[0xXXXXXXXXXXXXXXXX,0xXXXXXXXXXXXXXXXX],Num. of WWNs=2],
+Num. of PPC Group=1
[Perf Ctrl]
XP Performance Control (Perf Ctrl) function
184 XP Performance Control (Perf Ctrl) Function