HP StorageWorks XP24000/XP20000 Audit Log Reference Guide (AE131-96085, May 2011)

Table 220 Set All Prio WWN Operation
DescriptionItem
The setting status of the All Thresholds value in the WWN tab
Enable: All Thresholds value is set
Disable: All Thresholds value is cancelled
AllPriority
The All Thresholds value set.
This value is output only when the All Thresholds value is set
Threshold
The rate type of the All Thresholds value.
IOPS: I/O rate, KB/s: Transfer rate
This value is output only when the All Thresholds value is set.
Mode
Set Ctrl Kind Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Perf Ctrl],Set Ctrl Kind,Kind=WWN,Normal end,,,
Seq.=xxxxx
[Perf Ctrl]
XP Performance Control (Perf Ctrl) function
Set Ctrl Kind
Set Ctrl Kind operation
Kind=WWN
WWN is selected as the parameter. The operation uses the following parameters, as shown in
Table 221 (page 182).
Table 221 Parameters for Set Ctrl Kind Operation
DescriptionParameter
Port Control is applied without the All Thresholds value being set.Port
Port Control is applied with the All Thresholds value being set.All Port
WWN Control is applied. This value is output whether the All Thresholds value is set or
not.
WWN
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295).
Set Priority (Prio) Port Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Perf Ctrl],Set Prio Port,,Normal end,,,
Seq.=xxxxx +{Port,Priority,Use,Threshold/Upper Limit,Mode}=[{1A,Non-Prio,
Enable,XXXXXXXX,IOPS},{3A,Prio,Disable,,}],Num. of Ports=2
[Perf Ctrl]
XP Performance Control (Perf Ctrl) function
Set Prio Port
Set Prio Port operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
182 XP Performance Control (Perf Ctrl) Function