HP StorageWorks XP24000/XP20000 Audit Log Reference Guide (AE131-96085, May 2011)
Table 161 Uninstall Operation (Uninstalling a Shared Memory Module)
DescriptionItem
The mounting location of the PCB for shared memory.SM
The slot position of the shared memory module.Slot
The capacity of the cache memory module.Size
The number of shared memory modules.Num of SMMs
The flags of the options.PP Flag
The number of the flags of the options.Num of PP Flags
The maximum number of CUs.Max Number of
CUs
The mounting location of the batteryBattery
Indicates the installation or the uninstallation of the battery.
Install: Install battery, Uninstall: Uninstall battery.
Define
The number of batteries.Num. of Batteries
NOTE: Only the changed items will be output.
Example 5 (uninstalling a power supply)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],Uninstall,,Normal end,,,Seq.=xxxxx
+Redundant Power Supply=[CL Additional Power Supply,CL Additional Power Supply2],
Num. of Redundant Power Supplies=2
[Install]
Install function
Uninstall
Uninstall operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 162 (page 146).
Table 162 Uninstall Operation (Uninstalling a Power Supply)
DescriptionItem
The uninstalled additional cluster power supply.Redundant Power
Supply
The number of additional cluster power supplies.Num. of Redundant
Power Supplies
Example 6 (uninstalling a battery)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],Uninstall,,Normal end,,,Seq.=xxxxx
+Power Lost Mode=Memory Backup Mode
+Battery=[BATTERY-UR00,BATTERY-UR01,BATTERY-UR02,BATTERY-UR03],Num. of Batteries=4
[Install]
Install function
Uninstall
Uninstall operation
146 Install Function