HP StorageWorks XP24000/XP20000 Audit Log Reference Guide (AE131-96085, May 2011)
Set Speed Mode Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],Set Speed Mode,,Normal end,,,Seq.=xxxxx
+CHA=CHA-1E
++{Port Block,Mode}=[{A,High Speed},{B,High Speed}Num. of Blocks=2
+CHA=CHA-1H
++{Port Block,Mode}=[{A,Standard},{B,High Speed}],Num. of Blocks=2
+Num. of CHAs=2
[Install]
Install function
Set Speed Mode
Set Speed Mode operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 153 (page 139).
Table 153 Set Speed Mode Operation
DescriptionItem
The CHA name (name of channel adapter).CHA
The port block. Port blocks A and B are output.Port Block
The mode set to the port.
Standard: Standard mode. High Speed/MIX: High speed mode/Mix mode.
Mode
The number of port blocks in the channel adapter.Num. of Blocks
The number of channel adapters that the mode is changed.Num. of CHAs
Set Subsystem Time Operation
Example 1 (The case of TOD Change)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],Set Subsystem Time,TOD Change,
Normal end,,,Seq.=xxxxx
+Time=YYYY/MM/DD HH:mm:SS
Example 2 (The case of Synchro. Infor.)
For IPv4
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],Set Subsystem Time,Synchro. Infor.,
Normal end,,,Seq.=xxxxx
+{Use Synchro.,SNTP IP,SNTP Port,Time Zone,Check Time}={Valid,(123.456.789.123),100,
Tokyo Standard Time,24}
For IPv6
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],Set Subsystem Time,Synchro. Infor.,
Normal end,,,Seq.=xxxxx
+{Use Synchro.,SNTP IP,SNTP Port,Time Zone,Check Time}
={Valid,(1111.1111.1111.1111.AAAA.AAAA.AAAA.AAAA),100,
Tokyo Standard Time,24}
[Install]
Install function
Set Subsystem Time
Set Subsystem Time operation
TOD Change and Synchro. Infor
TOD Change is the selected parameter for example 1, and Synchro. Infor is the selected parameter
for example 2. This operation uses the following parameters, as shown in Table 154 (page 140).
Set Speed Mode Operation 139