HP StorageWorks XP24000/XP20000 Audit Log Reference Guide (AE131-96085, May 2011)
Install Operation
Example 1 (installing additional channel adapters)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Install],Install,,Normal end,,,Seq.=xxxxx
+{CHA,Kind}={CHA-1LU,16FS Fibre 8ch-4mp},
++{Port,Fibre PCB Mode,Initiator/Target,Channel Speed,CU Number}
=[{9J,Standard,Target,Auto,00:00-00:FE},{BJ,Standard,Target,Auto,00:00-00:FE},
-{DJ,Standard,Target,Auto,00:00-00:FE},{FJ,Standard,Target,Auto,00:00-00:FE},
{9K,Standard,Target,Auto,00:00-00:FE},{BK,Standard,Target,Auto,00:00-00:FE},
-{DK,Standard,Target,Auto,00:00-00:FE},{FK,Standard,Target,Auto,00:00-00:FE}],
Num. of Ports=8
+{CHA,Kind}={CHA-1KU, 8M MFibre 4ch-4mp},
++{Port,HTP/FNP,CU,Number,Emulation}=[{9N,HTP,00:00-00:3F,H-6591-2},
{BN,HTP,00:00-00:3F,H-6591-2},{DN,HTP,00:00-00:3F,H-6591-2},{FN,HTP,00:00-00:3F,
H-6591-2}],
Num. of Ports=4
+{CHA,Kind}={CHA-2XU,16FS Fibre 8ch-4mp},
++{Port,Fibre PCB Mode,Initiator/Target,Channel Speed,CU Number}
=[{AJ,Standard,Target,Auto,00:00-00:FE},{CJ,Standard,Target,Auto,00:00-00:FE},
-{EJ,Standard,Target,Auto,00:00-00:FE},{GJ,Standard,Target,Auto,00:00-00:FE},
{AK,Standard,Target,Auto,00:00-00:FE},{CK,Standard,Target,Auto,00:00-00:FE},
-{EK,Standard,Target,Auto,00:00-00:FE},{GK,Standard,Target,Auto,00:00-00:FE}],
Num. of Ports=8
+{CHA,Kind}={CHA-2WU, 8M MFibre 4ch-4mp},
++{Port,HTP/FNP,CU Number,Emulation}=[{AN,HTP,00:00-00:3F,H-6591-2},
{CN,HTP,00:00-00:3F,H-6591-2},
{EN,HTP,00:00-00:3F,H-6591-2},{GN,HTP,00:00-00:3F,H-6591-2}],Num. of Ports=4
+Num. of CHAs=4
[Install]
Install function
Install
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 122 (page 120).
Table 122 Install Operation (Installing Additional Channel Adapters)
DescriptionItem
The CHA) mounting location.CHA
The kind of PCB mounted.Kind
The mounting location of the port.Port
The speed mode of the Fibre PCB is indicated for open systems.
<Standard>: Standard mode. <High Speed/MIX>: High speed mode/Mix mode.
Fibre PCB Mode
The type of Initiator or Target.Initiator/Target
The channel speed is indicated for open systems.
1: 1 Gbps, 2: 2 Gbps, 4: 4 Gbps, 8: 8 Gbps, Auto: Auto mode.
Channel Speed
Indicates the range of the CU number which the port belongs.CU Number
The number of ports.Num of Ports
The HTP or FNP is indicated for FICON.HTP/FNP
The LCP is indicated for ESCON.LCP
The emulation type is indicated for mainframe systems.Emulation
The number of CHAs.Num. of CHAs
Example 2 (installing additional subsystems, ECC Groups or LDEVs)
120 Install Function